Product: Gas Dehydration Package
Design: Skid-mounted or modular system designed to remove water vapor from natural gas streams to prevent hydrate formation and corrosion in pipelines and process facilities
Type Options:
Glycol Dehydration Units (TEG) – continuous absorption and regeneration
Molecular Sieve Packages – adsorption-based with regeneration cycles
Solid Desiccant Systems – silica gel, alumina, activated carbon
Capacity Range: Configurable for flow rates from small wellhead units to large plant-scale systems
Pressure Rating: Up to ANSI Class 1500 / PN 250 (per process design)
Material Options: Carbon Steel, Stainless Steel, Duplex, Alloy Steel, Internally Coated for Corrosion Resistance
Operation: Manual or Fully Automated (PLC/SCADA controlled)
Temperature Range: -20°C to +200°C (depending on process medium and design)
Applications: Natural Gas Processing, LNG Plants, Petrochemical Facilities, Refineries, Gas Transmission Pipelines, Power Generation
Special Features:
Dew point control to pipeline specifications
Energy-efficient regeneration options
Sour service compliance (NACE MR0175)
Skid-mounted, plug-and-play installation
Designed for continuous operation with minimal downtime
Standards: API 12J / ASME Section VIII Div.1 / ASME B31.3 / ISO 9001

Measuring range : 200Pa-10MPa
Output signal : 4-20mA, 4~20mA/HART
Accuracy : ±0.075% URL, optional ±0.05% URL
Media temperature : -40-120℃
Power supply : 4~20mA two wire, 10.5-55vdc 4~20mA+HART two wire, 16.5-55vdc
Diaphragm material : SUS316L, Hastelloy C

Measuring range : 4kPa-1MPa
Output signal : 4-20mA, 4~20mA/HART
Accuracy : ±0.2% URL, ±0.5% URL
Media temperature : -40-120℃
Diaphragm material : SUS316L, Hastelloy C

Product : Pressure Transmitter
Range : Vacuum To 2200 bar
Long Term Drift : 0.25% FS/YR (non-cumulative)
Wetted Parts : 17-4 PH Stainless Steel
Supply Voltage : 8-30 V DC
Output(2-wire) : 4-20 mA / 0-10 V /1 -5 V
Output signal : 4-20mA, 4-20mA+HART, 0-5VDC

Designed for : RTD PT100 & Thermocouples (Universal input)
Output : Signal 4-20mA two wires
Configurable measuring ranges
Large ambient temperature range
Compact and inexpensive

Sensor Range : -200 to 850 °C [18 to 390 Ω]
Minimum Span*¹ : 25 °C
Measurement Accuracy : ± 0.01 % FRI*³ ± 0.05 % rdg
Thermal Drift Zero : 0.008 °C/°C
Excitation Current : 300 to 550 µA
Span : 0.01 %/°C
Accuracy : (±0.1%) of Span
Maximum Lead Resistance : 50 Ω/leg
Lead Resistance Effect : 0.002°C/Ω

Model : Fisher, Rosemount – Emersons Liquid level, Specific, Gravity or Interface Level
Application : Liquide Level, Specific, Gravity or Interface Level
Displacer Length : 100 mm to 4.5 Meter
Min. Differential Specific Gravity : 0.30 to 1.2 & 0.5
Accuracy : +/-0.5% of full scale (better on request)
Hazardous Area : ATEX, UL
Material Of Construction : Compatible Material of construction available for different process media. Can replace Fisher/ Masoneilin/ Yamatake/Motoyama/ parcol/ Eckard Transmitter, one to one…

Measuring Range(mm) : 500-3500
Process Pressure : Max, 6O bar
Switch Rating : 250VAV12 ;2.5 A/220 V DC13; 0.3 A
Protection Enclosure : IP65
Features(Optional) : Switches/Transmitter, ATEX, FM, UL
Output : 4-20 mA/ HART
Switch : SPDT, SPST, DPST

Max.flow rate : 200kg/min
Wetted parts : Stainless steel 316L
Sensor housing : Stainless steel 304
Fluid temperature : -200~200°C
Temp. Accuracy : ±1°C
Operating Voltage : AC85~265V,DC24V
Petronova Oilfield Equipments & Spare Parts Trading LLC is a diversified oilfield supply and construction industry company, offering a complete range of engineering products and equipment to meet the needs of the energy sector.